                             6400 RS232 Command List

                                                           92.01.27 - mng


        This document describes version 1.30 of the 6400 software.  Some 
        notes are included describing changes since earlier version but 
        this is by no means a comprehensive list.  Due to the amount of 
        additions made in the RS232 interface with the release of version 
        1.30 it is recommended that all 6400s being controlled through 
        the RS232 interface be upgraded to this release.

        We recommend you check what options are installed on a 6400 with 
        the "Get Version" command rather than check the error code at 
        each command.

        The RS232 command set recognized by the 6400 can be divided into 
        two categories, the first set contains those commands recognized 
        at any time the 6400 issues polls, the other set changes 
        depending on what operating mode the 6400 is in.

        The commands that are always recognized are:

        Command name                    Command number          Notes
        -------------------------------------------------------------
        Set Keyboard Control                    62              2
        Set Keycode                             72              2

        Do Reset                                38
        Do Error                                67              2

        Get Version                             28
        Get Status                              33
        Get Keycode                             58
        Get Instrument State                    60              2
        Get Keyboard Control                    63              2


        The remaining commands are divided according to what operating 
        mode the 6400 is in when the command is issued.

        Multi-Curve:

        Command name                    Command number          Notes
        -------------------------------------------------------------
        Set Label Information                    6              
        Set Curve Frame Data                     9

        Get Curve Frame Data                    25







                                        1


        Probe Option:

        Command name                    Command number          Notes
        -------------------------------------------------------------
        Set Source Amplitude Value               0
        Set Frequency Value                      2
        Set Noise Reduction Value                4
        Set Smoothing Status                     5
        Set Label Information                    6              
        Set Curve Frame Data                     9
        Set Gain Status                         12
        Set Automatic Status                    48
        Set Output Limiting Value               50
        Set Reference Microphone Status         52
        Set Active Status                       54
        Set Extended Label                      66              1

        Do Pure Tone Sweep                      16
        Do Level                                17
        Do Line Feed                            64              1
        Do Print                                65              1

        Get Source Amplitude Value              21
        Get Frequency Value                     23
        Get Curve Frame Data                    25
        Get Noise Reduction Value               26
        Get Smoothing Status                    27
        Get Gain Status                         36
        Get Most Recent Probe Curve Frame       42
        Get Automatic Status                    49
        Get Output Limiting Value               51
        Get Reference Microphone Status         53
        Get Active Status                       55
        Get Reference Microphone Data           57






        Notes:
        1) New command for release v1.30.




        -mng
        <eof>