                             6500 RS232 Command List
                                                               2005/02/14


        This document describes version 2.66 and higher of the 6500 
        software.  Some notes are included describing changes since 
        earlier version but this is by no means a comprehensive list.  
        Due to the number of important changes made in the RS232 
        interface with the release of version 2.66 it is recommended that 
        all 6500s being controlled through the RS232 interface be 
        upgraded to V2.66 or higher. See the file 6500NOTE.DOC for 
        information about previous releases of the RS232 software.

        Not all 6500s are configured with all possible options, it is not 
        in fact possible to install all possible options on a 6500, for 
        example the JIS and ISI options share the same key.  When a 6500 
        receives an RS232 command that requests some feature which is not 
        enabled it responds as if it did not understand the command by 
        returning an ACK packet and setting the error flag.  We recommend 
        you check what options are installed on a 6500 with the "Get 
        Version" command rather than check the error code at each 
        command.

        The RS232 command set recognized by the 6500 can be divided into 
        two categories, the first set contains those commands recognized 
        at any time the 6500 issues polls, the other set changes 
        depending on what operating mode the 6500 is in.

        Commands marked with * are dynamic data get commands. The data 
        returned by these commands may not be valid the first time you 
        read the data after changing the operating state of the 6500. You 
        should read the data from the 6500 twice to insure that the data 
        is valid.

        Commands marked with ** are get curve commands. In composite 
        mode, real time curves are dynamic, and the data may not be valid 
        after changing the state of the instrument. 

        For more information on reading dynamic data and other 
        information on programming the 6500, see the 6500NOTE.TXT file.
        Except where noted (see 6500NOTE.TXT) the 6500 does not support 
        the Expanded command formats. 














                                        1


        The common commands that are always recognized are:

        Command          -- Common ---                   Notes    Number
        ----------------------------------------------------------------
        Set Keyboard Control ..............................2......... 62
        Set Keycode .......................................2......... 72
        Set Poll Delay ....................................3......... 73
        Set Average Frequency Set .........................4.......#. 82
        Set Measurement Settle Time .......................4.......#. 84
        Set Average Mode Delay  ...........................7.......#. 90
        Set Printer Selection .............................8......... 92

        Get Version ................................................. 28
        Get Status .................................................. 33
        Get Keycode ................................................. 58
        Get Instrument State ..............................2......... 60
        Get Keyboard Control ..............................2......... 63
        Get Poll Delay ....................................3......... 74
        Get Average Frequency Set .........................4.......#. 81
        Get Measurement Settle Time .......................4.......#. 83
        Get Default Label .................................6......... 86
        Get Average Mode Delay  ...........................7.......#. 91
        Get Printer Selection .............................8......... 93

        Do Reset .................................................... 38
        Do Error ..........................................2......... 67

        The remaining commands are divided according to what operating 
        mode the 6500 is in what the command is issued.

        Note: Commands 28 and 33 are always supported on all instruments 
        that follow the FIPP protocol. Generally, command 38 is supported 
        on all instruments that support the FIPP protocol, but the 
        effects of the command may be different.

        # Commands 81,82,83,84,90 and 91 are not available as common   
        commands in all instruments. It is recommended that you limit   
        the use to the test state where the command is appropriate.

        Be sure to check the other instrument command files to determine 
        which commands are common, and the instrument note file to 
        determine any differences between instruments for a command, as 
        well as any version related issues that might be important if you 
        intend to write a program that supports multiple instruments.





        Command        -- Cold (logo) Screen (0) --      Notes    Number
        ----------------------------------------------------------------
        Do Level .................................................... 17




                                        2


        Command    -- Chamber Mode / Main Loop (1) --    Notes    Number 
        ----------------------------------------------------------------
        Set Source Amplitude Value ................................... 0
        Set Distortion Status ..................(Puretone)............ 1
        Set Frequency Value .......................................... 2
        Set OES Status .........................(OES)................. 3
        Set Noise Reduction Value .................................... 4
        Set Label .........................................5.......... 6          
        Set Probe Mode .........................(Probe)............!!. 7
        Set Weighting Status ......................................... 8
        Set Curve Frame Data ......................................... 9
        Set I/O Parameters .....................(I/O)................ 10
        Set Telecoil Mode ........................................... 11
        Set Gain Status ............................................. 12
        Set Telecoil Parameter ...................................... 39
        Set Attack & Release Frequency Value ........................ 40
        Set Zeta Mode ..........................(Zeta)............... 43
        Set Insitu Mode ........................(Insitu)............. 47
        Set Instrument State ..............................2......... 59
        Set Extended Label ................................2......... 66
        Set Spectrum Values ...............................2......... 68
        Set Phase Values ..................................2......... 69
        Set Operating Parameters ..........................2......... 70
        Set CIC Status .........................(CIC)................ 88
        Set Default Label .................................6......... 89
        Get Attack & Release Data ................................... 18
        Get Battery Data ..........................................*. 19
        Get I/O Data ...........................(I/O)................ 20
        Get Source Amplitude Value .................................. 21
        Get Distortion Status ..................(Puretone)........... 22
        Get Frequency Value ......................................... 23
        Get OES Status .........................(OES)................ 24
        Get Curve Frame Data .....................................**. 25
        Get Noise Reduction Value ................................... 26
        Get Leveling Status ......................................... 29
        Get Weighting Status ...................(Composite).......... 30
        Get Measurement Data ......................................*. 31
        Get Distortion Data ....................(Puretone).........*. 32
        Get I/O Parameters .....................(I/O)................ 34
        Get Probe Mode .........................(Probe)...........!!. 35
        Get Gain Status ............................................. 36
        Get Telecoil Mode ........................................... 37
        Get Attack & Release Frequency Value ........................ 41
        Get Telecoil Parameter ...................................... 44
        Get Zeta Mode ..........................(Zeta)............... 45
        Get Insitu Mode ........................(Insitu)............. 46
        Get Operating Parameters ..........................2......... 71
        Get CIC Status .........................(CIC)................ 87
        Get Default Label .................................6......... 86







                                        3


        Command    -- Chamber Mode / Main Loop (1) --    Notes    Number 
        ----------------------------------------------------------------
        Do Attack & Release Test .................................!!. 13
        Do Battery Test ...................................1......!!. 14
        Do I/O Test ............................(I/O).............!!. 15
        Do Start/Stop (Pure Tone Sweep) ............................. 16
        Do Leveling ................................................. 17
        Do Line Feed ......................................2......... 64
        Do Print ..........................................2......... 65
        Do Measurement ....................................7......... 85


        Command      -- Telecoil Mode (7) --             Notes    Number 
        ----------------------------------------------------------------
        Set Frequency Value .......................................... 2
        Set OES Status ............................................... 3
        Set Noise Reduction Value .................................... 4
        Set Label .........................................1.......... 6
        Set Telecoil Mode ........................................!!. 11
        Set Telecoil Parameter ...................................... 39
        Set Instrument State ..............................2......... 59

        Get Battery Data ..........................................*. 19
        Get Frequency Value ......................................... 23
        Get OES Status .............................................. 24
        Get Curve Frame Data .....................................**. 25
        Get Noise Reduction Value ................................... 26
        Get Measurement Data ......................................*. 31
        Get Telecoil Mode ........................................!!. 37
        Get Telecoil Parameter ...................................... 44

        Do Battery Test ...................................1......!!. 14
        Do Start/Stop (Pure Tone Sweep) ............................. 16























                                        4


        Command      -- I/O Option (11) --               Notes    Number 
        ----------------------------------------------------------------
        Set Label .........................................1.......... 6
        Set I/O Parameters .......................................... 10
        Set Instrument State ..............................2......... 59

        Get I/O Data ................................................ 20
        Get I/O Parameters .......................................... 34

        Do I/O Test ..............................................!!. 15


        Command      -- Attack & Release (9) --          Notes    Number 
        ----------------------------------------------------------------
        Set Label .........................................1.......... 6
        Set Attack & Release Frequency Value ........................ 40
        Set Instrument State ..............................2......... 59

        Get Attack & Release Data ................................... 18
        Get Attack & Release Frequency Value ........................ 41

        Do Attack & Release Test .................................!!. 13


        Command       -- Coupler Multi-Curve (14) --     Notes    Number 
        ----------------------------------------------------------------
        Set Label .........................................1.......... 6
        Set Curve Frame .............................................. 9
        Set Instrument State ..............................2......... 59

        Get Curve Frame Data .....................................**. 25


        Command       -- Probe Multi-Curve (20) --       Notes    Number 
        ----------------------------------------------------------------
        Set Label .........................................1.......... 6
        Set Curve Frame Data ......................................... 9
        Set Instrument State ..............................2......... 59

        Get Curve Frame Data .....................................**. 25
















                                        5


        Command         -- Probe Mode (6) --             Notes    Number 
        ----------------------------------------------------------------
        Set Source Amplitude Value ................................... 0
        Set Frequency Value .......................................... 2
        Set Noise Reduction Value .................................... 4
        Set Smoothing Status ......................................... 5
        Set Label .........................................1.......... 6
        Set Probe Mode ............................................!!. 7
        Set Curve Frame Data ......................................... 9
        Set Gain Status ............................................. 12
        Set Automatic Status ........................................ 48
        Set Output Limiting Value ................................... 50
        Set Reference Microphone Status ............................. 52
        Set Active Status ........................................... 54
        Set Instrument State ..............................4......... 59
        Set Extended Label ................................2......... 66
        Set Default Label .................................6......... 89

        Get Source Amplitude Value .................................. 21
        Get Frequency Value ......................................... 23
        Get Curve Frame Data .....................................**. 25
        Get Noise Reduction Value ................................... 26
        Get Smoothing Status ........................................ 27
        Get Probe Mode ...........................................!!. 35
        Get Gain Status ............................................. 36
        Get Last Measured Curve Frame Data .......................**. 42
        Get Automatic Status ........................................ 49
        Get Output Limiting Value  .................................. 51
        Get Reference Microphone Status ............................. 53
        Get Active Status ........................................... 55
        Get Reference Microphone Data .............................*. 57
        Get Default Label .................................6......... 86

        Do Start/Stop (Pure Tone Sweep) ............................. 16
        Do Level .................................................... 17
        Do Line Feed ......................................2......... 64
        Do Print ..........................................2......... 65



















                                        6


        Command      -- Zeta Mode !! (8) --              Notes    Number 
        ----------------------------------------------------------------
        Set Source Amplitude Value ................................... 0
        Set Frequency Value .......................................... 2
        Set Noise Reduction Value .................................... 4
        Set Label .........................................1.......... 6
        Set Curve Frame Data ......................................... 9
        Set Zeta Mode ............................................!!. 43

        Get Source Amplitude Value .................................. 21
        Get Frequency Value ......................................... 23
        Get Curve Frame Data .....................................**. 25
        Get Noise Reduction Value ................................... 26
        Get Zeta Mode ............................................!!. 45


        Command       -- Average Mode (13) --            Notes    Number 
        ----------------------------------------------------------------
        Set Source Amplitude Value ................................... 0
        Set Frequency Value .......................................... 2
        Set Label .................................................... 6
        Set Instrument State ........................................ 59
        Set Extended Label .......................................... 66
        Set Default Label .................................6......... 89

        Get Source Amplitude Value .................................. 21
        Get Frequency Value ......................................... 23
        Get Default Label .................................6......... 86

        Do Line Feed ................................................ 64
        Do Print .................................................... 65

























                                        7



        Command          -- ANSI87 Mode (2) --           Notes    Number 
        ----------------------------------------------------------------

        Minor State #1 (Set max telecoil output)
        Set Instrument State ..............................2......... 59
        Get Measurement Data ......................................*. 31
        Get Blob ..........................................4......... 61
        Get Operating Parameters ..........................2......... 71

        Minor State #2 (Set aid to normal operation - after telecoil)
        Set Instrument State ..............................2......... 59
        Get Blob ..........................................4......... 61
        Get Operating Parameters ..........................2......... 71

        Minor State #3 (Set reference test gain)
        Set Instrument State ..............................2......... 59
        Get Blob ..........................................2......... 61
        Get Operating Parameters ..........................2......... 71

        Minor State #4 (Test complete)
        Set Label .........................................1.......... 6
        Set Instrument State ..............................2......... 59
        Set Extended Label ................................2......... 66
        Set Operating Parameters ..........................2......... 70
        Set Default Label .................................6......... 89
        Get Blob ..........................................2......... 61
        Get Operating Parameters ..........................2......... 71
        Get Default Label .................................6......... 86
        Do Line Feed ......................................2......... 64
        Do Print ..........................................2......... 65


        Command         -- ANSI92 Mode (12) --           Notes    Number 
        ----------------------------------------------------------------

        Minor State #1 (Set reference test gain)
        Set Instrument State ........................................ 59
        Get Blob .................................................... 61
        Get Operating Parameters .................................... 71

        Minor State #2 (Test complete)
        Set Label .................................................... 6
        Set Instrument State ........................................ 59
        Set Extended Label .......................................... 66
        Set Operating Parameters .................................... 70
        Set Default Label .................................6......... 89
        Get Blob .................................................... 61
        Get Operating Parameters .................................... 71
        Get Default Label .................................6......... 86
        Do Line Feed ................................................ 64
        Do Print .................................................... 65




                                        8


        Command     -- ANSI96/ANSI03 Mode (18/33) --     Notes    Number 
        ----------------------------------------------------------------

        Minor State #1 (Set reference test gain)
        Set Instrument State ..............................2......... 59
        Get Blob ..........................................2......... 61
        Get Operating Parameters ..........................2......... 71

        Minor State #2 (Set max telecoil output)
        Set Instrument State ..............................2......... 59
        Get Measurement Data ......................................*. 31
        Get Blob ..........................................4......... 61
        Get Operating Parameters ..........................2......... 71

        Minor State #3 (Set aid to normal operation - after telecoil)
        Set Instrument State ..............................2......... 59
        Get Blob ..........................................4......... 61
        Get Operating Parameters ..........................2......... 71

        Minor State #4 (Test complete)
        Set Label .........................................1.......... 6
        Set Instrument State ..............................2......... 59
        Set Extended Label ................................2......... 66
        Set Operating Parameters ..........................2......... 70
        Set Default Label .................................6......... 89
        Get Blob ..........................................2......... 61
        Get Operating Parameters ..........................2......... 71
        Get Default Label .................................6......... 86
        Do Line Feed ......................................2......... 64
        Do Print ..........................................2......... 65

        Note: ANSI03 was added with V4.90
























                                        9


        Command           -- IEC Mode (3) --             Notes    Number 
        ----------------------------------------------------------------

        Minor State #1 (Set reference test gain loop)
        Set Instrument State ..............................2......... 59
        Get Blob ..........................................2......... 61
        Get Operating Parameters ..........................2......... 71

        Minor State #2 (Test complete loop)
        Set Label .........................................1.......... 6
        Set Instrument State ..............................2......... 59
        Set Extended Label ................................2......... 66
        Set Operating Parameters ..........................2......... 70
        Set Default Label .................................6......... 89
        Get Blob ..........................................2......... 61
        Get Operating Parameters ..........................2......... 71
        Get Default Label .................................6......... 86
        Do Line Feed ......................................2......... 64
        Do Print ..........................................2......... 65


        Command         -- JIS Mode (4) --               Notes    Number 
        ----------------------------------------------------------------

        Minor State #1 (Set reference test gain)
        Set Instrument State ..............................2......... 59
        Get Blob ..........................................2......... 61
        Get Operating Parameters ..........................2......... 71

        Minor State #2 (Test complete)
        Set Label .........................................1.......... 6
        Set Instrument State ..............................2......... 59
        Set Extended Label ................................2......... 66
        Set Operating Parameters ..........................2......... 70
        Set Default Label .................................6......... 89
        Get Blob ..........................................2......... 61
        Get Operating Parameters ..........................2......... 71
        Get Default Label .................................6......... 86
        Do Line Feed ......................................2......... 64
        Do Print ..........................................2......... 65
















                                       10


        Command           -- DSIN Mode (17) --           Notes    Number 
        ----------------------------------------------------------------

        Minor State #1 (Digital Speech-In-Noise mode)
        Set OES Status .........................(OES)................. 3
        Set Noise Reduction Value .................................... 4
        Set Label .................................................... 6
        Set Weighting Status ......................................... 8
        Set Instrument State ........................................ 59
        Set Extended Label .......................................... 66
        Set Operating Parameters .................................... 70
        Set CIC Status .........................(CIC)................ 88
        Set Default Label .................................6......... 89
        Get OES Status .........................(OES)................ 24
        Get Curve Frame Data .....................................**. 25
        Get Noise Reduction Value ................................... 26
        Get Leveling Status ......................................... 29
        Get Weighting Status ...................(Composite).......... 30
        Get Measurement Data ......................................*. 31
        Get Operating Parameters .................................... 71
        Get CIC Status .........................(CIC)................ 87
        Get Default Label .................................6......... 86
        Do Line Feed ................................................ 64
        Do Print .................................................... 65

        Note: DSIN is New with V4.30






























                                       11


        Command         -- Profiler Mode (12) --         Notes    Number 
        ----------------------------------------------------------------

        Minor State #1 (Set full on gain)
        Set Instrument State ........................................ 59
        Get Operating Parameters .................................... 71

        Minor State #2 (Test complete)
        Set Label .................................................... 6
        Set Instrument State ........................................ 59
        Set Extended Label .......................................... 66
        Set Operating Parameters .................................... 70
        Set Default Label .................................6......... 89
        Set CIC Status .........................(CIC)................ 88
        Get Blob .................................................... 61
        Get Operating Parameters .................................... 71
        Get Default Label .................................6......... 86
        Get CIC Status .........................(CIC)................ 87
        Do Line Feed ................................................ 64
        Do Print .................................................... 65

        Note: Profiler is New with V4.50



        Command          -- Enhanced DSP (28) --         Notes    Number 
        ----------------------------------------------------------------

        Minor State #0 (Test Idle)
        Set Label .................................................... 6
        Set Instrument State ........................................ 59
        Set Extended Label .......................................... 66
        Set Operating Parameters .................................... 70
        Set Default Label .................................6......... 89
        Get Default Label .................................6......... 86
        Do Line Feed ................................................ 64
        Do Print .................................................... 65
        Get Delay Display Data ............................9........ 110
        Get Delay Measurements ............................9........ 131

        Note: Enhanced DSP support is new with V4.72















                                       12


        Notes:
        1) This command is obsolete and may be dropped in a future release.
        2) New command for release v2.66.
        3) New command for release v4.00.
        4) New command for release v4.03.
        5) This command does not work in V4.00-V4.02.
        6) New command for release V4.06
        7) New command for release V4.14
        8) New command for release V4.20
        9) New command for release V4.72

        *  This is a dynamic measurement
        ** Curves may be dynamic in composite mode
        !! Obsolete (but still functional) command. See Set/Get 
           Instrument State commands for the new method of controlling 
           the instrument state.








































                                       13


        <eof> -med























































                                       14
